Hull 240 square foot production freeze dryer with door open 450 square foot production freeze dryer with sub-door for autoloading 30 square foot research and pilot freeze dryer with water jacketed chamber and door 540 square foot production freeze dryer showing autoloading of vials onto a product shelf

"Advancing Lyophilization and Freeze Drying Equipment for Over Fifty Years"

 

 
Home
Contact

Products & Capabilities
Freeze Drying Support
About Hull
Industry Links

Site Map
Privacy Policy
Terms of Use
 
SP Industries :   news | events | employment
Return to Previous Page
 

TECH TIPS   by   Dave Clayton

Your Source for Technical Information


Compressor Discharge Pressure Problems

Symptom
Compressor Discharge Pressure Too High

Diagnosis
Non-condensables in system (nitrogen, oxygen, etcetera)

Solution
Identify cause; usually a leak to atmosphere

Diagnosis
System overcharged with refrigerant

Solution
Remove excess refrigerant

Diagnosis
Dirty condenser/receiver

Solution
Remove end caps and clean tubes

Diagnosis
Defective or improperly set water regulating valve

Solution
Set for proper operation (e.g. R507: 175 - 190 psig)

Diagnosis
Air in condenser/receiver water system

Solution
Vent air from system

Symptom
Compressor Discharge Pressure Too Low

Diagnosis
Low suction pressure

Solution
Lowest suction pressure should be adjusted to 24 - 25 inches Hg

Diagnosis
Shortage of refrigerant

Solution
Add sufficient refrigerant to eliminate bubbles in the sight glass

Diagnosis
Defective or improperly set water regulating valve

Solution
Set for proper operation (e.g. R507: 175 - 190 psig)

These technical tips are for use by qualified maintenance personnel who are familiar with their specific freeze drying equipment. These tips are intended only as general guidelines. Lyophilization equipment is frequently custom configured and some tips may not be appropriate for all freeze dryers. Always read and follow the directions of your equipment's maintenance manual. If you would like to discuss one of our tech tips, please contact Dave at 215-672-7800 ext-1376.